Independent · every fact sourced · reviewed by Jan Pospisil
The UK Multifoil Guide
The UK Multifoil Guide gives independent, sourced answers on multifoil and foil insulation in homes in England and Wales. Every fact is footnoted to its source, and the guide is reviewed weekly. Its publisher, SprayFoamCheck, is an independent inspector with nothing to sell except an inspection.
Last reviewed 26 November 2026 by Jan Pospisil, DEA qualified (ABBE Level 3)
Reviewed weekly: every fact checked against the news and its sources. Page last updated 26 November 2026.
Includes time-sensitive information: checked in the weekly sweepIndependent: SprayFoamCheck doesn't install or remove insulation and takes no referral fees.
- 32sourced pages, from air gaps and condensation to foil fitted after spray foam removal
- 80sources: product approvals, building regulations and public bodies, each one linked
Start with your situation
- Foam removed and foil fittedThe paperwork, the product, eaves and ventilation, battens, taped joints, extra insulation.
- Offered removal and a foil refitQuestions to ask before signing, the refit in writing, reported prices, cancelling.
- Someone called about foil insulationAgreeing to nothing, noting the call, checking the firm's claims, reporting it.
- Buying a home with multifoilFinding out what is there, the paperwork to request, the product approval.
- Selling a home with multifoilGathering the paperwork, checking it matches what was fitted, the property form.
- Living with multifoil: should I worry?What you have, condensation signs, heat sources, keeping vents and eaves clear.
- Thinking of having multifoil fittedWhat to ask about the product, its approval, the calculation, battens, ventilation.
- Working in property or building controlStandards and their dates, values the approvals declare, what is not published.
Not sure where to start?
Answer up to four questions to find the right page. Nothing you enter is sent anywhere.
Step 1 of 4
What best describes your situation?
Questions people ask
Is foil insulation any good?
Laboratory tests measured less than comparison tests claimed. LABC reported in April 2008 that NPL hot-box tests gave 1.69 to 1.71 m²K/W of thermal resistance, against comparative-test claims of 5 to 6.[1] The same note says products with a product approval are acceptable when used strictly as it sets out.[1] Read more: does multifoil work?
Does foil insulation need an air gap?
Yes. BRE's U-value conventions (BR 443, 2019 edition) say a foil surface adds thermal resistance only where it faces an air space, and beyond 25 mm an unventilated cavity keeps the same resistance.[2] The three BBA approvals we opened count an unventilated roof cavity from 13 mm; two count a wall cavity from 20 mm.[3][4][5] Read more: air gaps explained
Does foil insulation cause condensation?
It depends how it is fitted. Two BBA approvals we opened say the space under a roof underlay (felt) with a high vapour resistance should be ventilated.[3][5] A Cornwall energy charity's page, which carries a Cornwall Council Trading Standards warning (undated), says foil added to a loft can trap moisture in the rafters.[6] Read more: foil and condensation
Is multifoil a vapour barrier or breathable?
It depends on the type. The under-rafter multifoils whose BBA approvals we opened can act as vapour control layers (vapour barriers) when laps and joints are sealed.[3][4][5] The one breathable multifoil whose approval we opened (Kiwa, June 2021) is for use over rafters, not under them.[7] Read more: what is multifoil?
Does multifoil meet building regulations on its own?
Not in the product approvals we opened: every worked example in the three BBA approvals includes other insulation.[3][4][5] One says additional insulation "will be required" to meet national thermal requirements.[3] England's 2021 Approved Document L gives 0.15 W/m²K as the U-value for a new or replacement roof element in an existing home.[8] Read more: building regulations
Is multifoil really equal to 200 mm of mineral wool?
A press report and one independent writer say the claim rests on a comparison test, not a laboratory value: 25 mm of multifoil against 200 mm of mineral wool in two chalets in France in about 1997.[9][10] The Advertising Standards Authority (ASA) upheld a complaint about it, an undated article in Building says.[9] Read more: multifoil's UK history
I had spray foam removed and foil fitted: how do I know it was done properly?
Check it against the product approval for that foil. The three BBA approvals we opened set out taped laps and battens over the foil, and their worked examples include other insulation.[3][4][5] Not every installation is a problem, and an inspection records only what can be seen and measured. Read more: after spray foam removal
What should replace spray foam after removal?
If the foam is removed, we found no public body's guidance on what should replace it, as of 10 November 2026. RICS's spray foam guide (March 2023) prefers ceiling-level insulation where the loft is not lived in.[11] No under-rafter multifoil approval we opened covers a loft insulated at ceiling level.[3][4][5] Read more: replacing spray foam
Is my multifoil's BBA approval still valid?
UKAS said on 15 June 2026 that existing BBA approvals remain valid until they expire.[12] UKAS suspended the BBA on 26 February 2026. The latest end date in UKAS's statement, 25 November 2026, has passed; UKAS had published no update when we checked on 26 November 2026, and the BBA's home page still said the suspension was in place.[12][13] We have not checked any approval on the BBA's register. Read more: product approvals
Is foil insulation flammable?
Multifoil can burn, according to the three BBA approvals we opened: they say their multifoils melt and shrink from heat but burn in a naked flame, and with a lining board are contained between the roof and the board.[3][4][5] All four approvals we opened say the multifoil must not touch heat sources above 80 °C.[3][4][5][7] Read more: fire safety
All topics
After spray foam removal
- Multifoil fitted after spray foam removal — what the product approvals require of the foil, what public bodies have reported, and what stays hidden.
- Quoted for spray foam removal and multifoil? — questions to ask about the refit, prices public bodies have reported, and your right to cancel.
- What insulation should replace spray foam after removal? — what RICS, the Energy Saving Trust and the product approvals say about each option.
- Spray foam removed and foil fitted — step by step: paperwork, product, eaves, ventilation, battens, taped joints and extra insulation.
- Offered spray foam removal and a foil refit — step by step before you sign: what to ask, reported prices and cancelling.
Basics
- What is multifoil insulation? — how it works, the two main types, and how it differs from bubble foil and boards.
- How do I know if I have multifoil? — what the approvals describe, where it is fitted, what paperwork shows and what stays hidden.
- Multifoil in the UK: the 2007 court case — whether it was ever banned, the 200 mm claim, and the rules from 2006 to 2026.
- Multifoil glossary: the terms explained — plain definitions of the terms this guide uses, from air gap to U-value.
Installation and performance
- How to check multifoil was installed properly — the conditions the product approvals set, what can be checked, and what plasterboard hides.
- Does foil insulation need an air gap? — where the 13, 20 and 25 mm figures come from, and what a smaller gap does.
- Does foil insulation cause condensation? — vapour control, taped joints, old bitumen felt, ventilation and cold lofts, from approvals and standards.
- Is foil insulation flammable? — fire classes in the approvals, plasterboard linings, flues, cables and downlights, and what is not known.
- Multifoil product approvals: BBA, Kiwa and LABC documents — what an approval shows and does not show, its conditions, and whether yours is current.
- Does multifoil insulation work? — what laboratory tests and product approvals report, and where the 200 mm claim comes from.
- Multifoil and building regulations — roof U-values, how multifoil is counted in a calculation, and what changes in 2027.
- Multifoil insulation problems: what goes wrong and why — sales claims, missing air gaps, untaped joints, condensation, cold lofts and paperwork that does not match.
- Is foil insulation good for lofts? — cold loft or room in the roof, what approvals cover and what public bodies say.
- Multifoil or rigid board? How the two compare — thickness, vapour control and fire classes, and why the approvals use the two together.
- What paperwork should you have for multifoil insulation? — contract, product approval, U-value calculation, building control record and warranty, and what if any is missing.
- Living with multifoil: should I worry? — step by step: what to look for, what to keep clear and what paperwork to keep.
- Thinking of having multifoil fitted? — step by step: where the approvals apply and what to ask for before you sign.
Buying and selling
- Buying or selling a house with multifoil — what the TA6 property form asks, what we found published on surveys, and paperwork to gather.
- Buying a home with multifoil: step by step — find out what was fitted, ask for the paperwork, and check the product approval.
- Selling a home with multifoil: step by step — gather the paperwork, check it names the same product, and know what the form asks.
Rights and sales practices
- Cold calls about foil insulation and foam removal — what Trading Standards have reported, how to check a caller, and where to report a call.
- Multifoil gone wrong: your rights and Section 75 — the 14-day right to cancel, reasonable care and skill, Section 75 and ombudsman decisions as examples.
- Someone called about foil insulation: what to do — step by step: agree to nothing, note the call, check the firm and report it.
Reference
- Multifoil claims we checked against the original sources — claims from other sites, each one traced, corrected or marked as having no source found.
- What's changed: multifoil news and updates — a dated log of rule changes, approval status and public warnings, newest first.
For professionals
- Multifoil: a reference for professionals — standards, declared values, conditions and dates for building control, surveyors, conveyancers and developers.
What's changed recently
- 26 November 2026: the latest end date UKAS gave for the BBA's suspension, 25 November 2026, has passed. UKAS had published no update when we checked on 26 November 2026, and the BBA's home page still said the suspension was in place.[12][13]
- 20 November 2026: this guide was published. The BBA's UKAS status, suspended since 26 February 2026, was still suspended when we checked.[12]
- 10 November 2026: the BBA's UKAS status, suspended since 26 February 2026, was still suspended.[12][13]
- 10 September 2026: a government consultation on consumer protection for home upgrade schemes closed; no outcome published as of 10 November 2026.[14]
- 8 September 2026: a revised copy of England's 2026 Approved Document L was published, with minor corrections.[15][16]
- 28 August 2026: the Property Care Association (PCA), a trade body, was reported to have opened a membership branch for spray foam removal contractors.[17]
How this guide is written
How this guide is written
Primary sources come first: official documents, standards bodies' records and product approvals, opened and read. Every fact is footnoted to its source. Anything not opened is left out or marked. Claims from other sites are checked against the original sources in claims we checked. No installer, removal firm, claims firm or law firm is named. Manufacturers are never ranked or recommended. The guide is reviewed weekly, and anything that can change is dated. It is written by Jan Pospisil of SprayFoamCheck, an independent inspector with no link to any installer or removal firm.
The UK Spray Foam Guide
Our sister guide is The UK Spray Foam Guide. Where the law is the same for both, this guide links to its pages. The spray foam guide also covers what to check in a loft straight after removal.
Get the foil checked independently
A Multifoil / Foil Inspection records what is fitted, how it is fixed and sealed, the air gaps and ventilation that can be seen, and moisture readings at the timbers that can be reached.
Report within 48–72 hours of inspection. Independent: no installation, no removal, no referral commissions.
Travel included within about three hours of the North West; a fixed supplement further away, shown with your total before you book.
It's evidence for your own decisions. It records what can be seen and measured, and says what is hidden.
Questions first? Call or WhatsApp 07349 718935 WhatsApp (opens in a new tab)
Sources
17 sources, numbered as cited in the text. Tap a footnote number to jump to its source.